Skip to main content

jimmylea

​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​Multiphase Flow Simulation

Multiphase Flow and Pipe Network Analysis

jimmylea provides multiphase flow simulation and pipe network analysis to help clients understand and optimise complex piping systems involving gas, liquid and solid phases. Our process engineers use appropriate simulation methods to analyse pressure drop, flow distribution, phase behaviour, solids transport and hydraulic performance across piping systems and networks. Whether the task involves gas-liquid flow, slurry transport, three-phase flow, pump sizing, network balancing or troubleshooting, our analysis provides practical engineering insight to support reliable and efficient operation.

Our team conducts detailed analysis across single-loop and multi-loop piping networks, considering pipe geometry, fittings, valves, pumps and operating conditions. We investigate pressure drop, flow distribution, phase behaviour, solids settling and potential hydraulic bottlenecks that can affect system performance. Depending on the engineering problem, analysis may range from one-dimensional pipe-network modelling and process simulation to detailed computational fluid dynamics.

Multiphase Flow Behaviour and System Performance

Multiphase flow through piping systems can exhibit complex behaviour including phase separation, flow-regime changes, solids settling, deposition, maldistribution and flow instabilities. Gas-liquid, liquid-solid and gas-liquid-solid systems can behave substantially differently from conventional single-phase flow, affecting pressure drop, transport capacity and overall hydraulic performance.

For piping systems, our process engineers conduct hydraulic analysis across single-loop and multi-loop networks to evaluate pressure drop, flow distribution, pump requirements and system balancing. We help identify hydraulic bottlenecks, cavitation risks, velocity imbalances and other conditions that can affect reliability and energy efficiency.

Why Engage Us to Conduct Multiphase Flow Analysis?

Multiphase piping problems such as phase maldistribution, solids deposition, excessive pressure drop, cavitation and flow imbalance can reduce system performance, damage equipment and cause unplanned downtime. By integrating multiphase flow simulation with pipe network and hydraulic analysis, jimmylea applies engineering judgement to identify the underlying flow behaviour and develop practical solutions for piping system design, optimisation and troubleshooting.

Below are selected multiphase flow and pipe network simulation projects that we have delivered across the chemical, energy, resources, water, semiconductor and nanotechnology industries.

Multiphase flow is an important area of chemical engineering, combining fluid dynamics, transport phenomena and process engineering principles, as recognised by the Institution of Chemical Engineers (IChemE).

Multiphase Flow Simulation

Pipe Flow Simulation of a PCW network with Additional Equipment Load

In this project, we performed a pipe flow simulation to evaluate whether the existing piping system could adequately accommodate the installation of an additional 23 sets of equipment. The study modelled the current pipework layout, including mains and lateral branches, to analyse the impact of the new connections on flow distribution, pressure drops and velocity variations. The system featured multiple lateral take-offs feeding the new equipment, with colour-coded results highlighting velocities across the network and pinpointing locations of increased hydraulic demand.

This hydraulic analysis revealed additional pressure losses due to frictional effects and longer flow paths, while some branches exhibited higher velocities and uneven load sharing. Critical junctions were assessed for their ability to sustain the required flows without overloading specific laterals or exceeding recommended pipe sizing. High-velocity segments and localised pressure drops indicated areas that may require reinforcement, resizing or design adjustments.

This hydraulic analysis provided insights into system adequacy, identified potential bottlenecks, and quantified whether the existing pipework could sustain the expanded demand. The results supported decision-making on whether to retain the current network with minor modifications or implement design upgrades to ensure balanced, reliable and efficient operation after expansion.

Pipe Flow Study

Pipe Flow Simulation and Pump Sizing

We have delivered a project involving the pipe flow simulation of a fluid transport system to assess its hydraulic performance and determine the pressure drop for appropriate pump sizing. The system comprised interconnected pipes, nodes and components, with a consistent flow velocity of 1.968 metres per second throughout. The simulation revealed a gradual pressure reduction caused by frictional losses, elevation changes and system fittings, starting at 0.2033 bar gauge at the storage tank and decreasing to -0.1584 bar gauge near the pump inlet. 

The pump at PU 4002 played a critical role in overcoming these losses to maintain the required flow rate and pressure for fluid delivery to the outlet. Based on this hydraulic analysis, we calculated the total head loss to guide pump selection and ensure efficient operation without issues such as cavitation or insufficient outlet pressure.

Hydraulic analysis

Pipe Flow Simulation of Complex Network

In this project, we conducted pipe flow simulation that modelled a complex network of interconnected pipelines, tanks and components to analyse flow distribution, pressure drops and velocity variations. The system featured multiple branching paths with flow splitting at various junctions to ensure fluid delivery to end-use points. The colour-coded pipes indicated velocities ranging from 0.222 to 7.605 m/s, highlighting areas of high flow concentration. 

The pipe flow simulation revealed pressure drops resulting from frictional losses, flow division and elevation changes, with pressure varying across nodes. High-velocity segments identified potential bottlenecks and areas requiring design adjustments to reduce pressure losses and minimise pipe wear. The branching design balanced flow distribution across parallel paths to avoid overloading specific sections.

This pipe flow simulation provided critical insights that supported design optimisation, improved efficiency, reduced losses and enabled proper sizing of pumps and other system components. The results helped refine the design to achieve reliable and balanced performance across the entire network.

Pipe Flow Modelling

Hydraulic Analysis

Project performance depends on the actual piping layout, elevation profile and hydraulic resistance. We therefore conducted a hydraulic analysis to predict real operating behaviour, quantify head losses, validate pump arrangements and ensure reliable service under site conditions.

We were commissioned to assess two options: pumps in parallel and pumps in series. Two separate simulations were run, one per configuration, to evaluate how each arrangement affects achievable flow rate and discharge pressure. The results allowed a direct comparison of head and flow, highlighting where each option best meets the stated operational requirements. Through our hydraulic analysis, we design piping networks with pump configurations tailored to meet client objectives and operational needs.

The following sections present the simulated outcomes for both arrangements, comparing pump performance and overall system behaviour to support selection decisions.

Pumps in Parallel

Pumps in Series

The diagram below illustrates the performance of pumps configured in parallel, comparing the behaviour of a single pump versus two pumps. In this configuration, the two pumps operate simultaneously to handle the fluid flow. The graph plots head (H) on the vertical axis and flow rate (Q) on the horizontal axis, showing how the combination of two pumps significantly enhances the system’s capacity. The two-pump curve is positioned above the single-pump curve, indicating a marked increase in flow rate while maintaining a similar head.

This parallel arrangement is particularly beneficial in applications where the system requires higher flow rates without a significant rise in pressure. By using two pumps in parallel, it becomes possible to efficiently transport more fluid through the system while avoiding excessive pressure increases. This makes the parallel configuration ideal for situations where the primary objective is to improve flow capacity without overloading the system or causing wear due to high-pressure conditions.

The diagram below illustrates the performance of pumps arranged in series, highlighting the difference between a single pump and two pumps in this configuration. When pumps are connected in series, the two-pump curve is significantly elevated above the single-pump curve. This indicates a substantial increase in head (H) while the flow rate (Q) remains almost unchanged.

This series configuration is particularly advantageous for systems where increased pressure is a priority over higher flow rates. It is commonly employed in applications requiring a boost in system pressure to overcome resistance in the pipeline, deliver fluid to elevated locations, or meet other high-head requirements. The arrangement ensures that the energy added by each pump is cumulative, making it an effective solution for challenging pressure demands without altering the flow rate substantially.

Pump parallel arrangement
Pump series arrangement

Pipe Flow Simulation to Determine Pump BEP

jimmylea was engaged to conduct a pipe flow simulation to determine the pump’s Best Efficiency Point (BEP) under actual system conditions. The image below illustrates the fundamental relationship between a pump and the hydraulic system in which it operates, providing insight into how operating conditions determine pump performance and efficiency. It shows two critical curves: the pump curve (red) and the system curve (blue), with their intersection defining the operating point. The selected point in this diagram is the Best Efficiency Point (BEP).

Pump Curve

The pump curve (red) represents the inherent characteristic of the pump itself, usually supplied by the manufacturer. It plots the head (H) that the pump can deliver against the flowrate (Q). At low flowrates, the pump produces high head because most of the energy imparted by the impeller is retained as pressure energy rather than kinetic energy. As the flowrate increases, the head progressively drops since the pump’s capacity to maintain pressure diminishes due to hydraulic losses, recirculation, and velocity distribution effects within the impeller and volute. The shape of the curve is influenced by impeller geometry, rotational speed, and pump type (centrifugal, axial, or mixed flow). Accurate interpretation of the pump curve is critical to selecting equipment that operates within its efficient and reliable range.

 

System Curve

The system curve (blue) describes how the hydraulic resistance of the piping network varies with flowrate. It accounts for static head (height difference between suction and discharge reservoirs) and dynamic head (frictional and local losses that increase roughly with the square of flowrate). At zero flow, the system curve starts at the static head, while at higher flows, the curve rises sharply due to rapidly increasing frictional losses. This curve is unique to the hydraulic circuit in which the pump is installed and changes if valves are adjusted, pipework is modified, or fluid properties vary. Understanding the system curve allows engineers to predict the true operating point when matched with a pump curve.

Pump sizing consultants

Best Efficiency Point (BEP)

The Best Efficiency Point (BEP) is the actual operating condition of a pump-system interaction, defined by the intersection of the pump curve and the system curve. At this point, the head developed by the pump precisely balances the head demanded by the system at the same flowrate. The BEP represents the condition of maximum hydraulic efficiency and optimal hydraulic stability, where flow is uniformly distributed across the impeller, axial and radial thrusts are minimised, and vibration levels remain low. Operating at or near BEP reduces energy losses from flow separation, recirculation, cavitation risk, and vibration, thereby enhancing reliability and longevity.


Industrial practice typically specifies an acceptable operating range around BEP, often between 70-120% of the BEP flow, within which pumps can perform safely and efficiently. However, operation outside this range can lead to surging, cavitation, excessive shaft deflection, increased power consumption, and premature wear, making BEP the critical target for efficient and reliable pump operation in applications such as power plants, refineries, and water distribution systems.